Browse all practice questions for the Commercial Food Equipment Service Association (CFESA) Refrigeration Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

CFESA Refrigeration Certification Practice Test 2026 – The All-in-One Guide to Mastering Your Exam! course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What could happen if the condenser fan motor is not cleaned?
  • Which maintenance task is critical for evaporators?
  • Which part of the refrigeration system is crucial for removing moisture?
  • Which refrigerant serves as a drop-in replacement for R502?
  • Which factor is crucial when selecting a pump for evacuating refrigeration systems?
  • What should be done to a grease-laden air-cooled condenser?
  • Which statement is true regarding R134A?
  • What does the start relay disconnect when the motor reaches about 2/3 of its full speed?
  • In a potential relay, how is the coil typically wired?
  • What happens to the compressor when the condensing temperature at the compressor head reaches 350 °?
  • What effect does insufficient refrigerant charge have on a refrigeration system?
  • Excessive moisture in a reach-in cooler typically suggests what issue?
  • In what way does the refrigeration cycle specifically differ from the air conditioning cycle?
  • What action is needed to ensure the suction pressure remains the same during testing?
  • In a system with R134A operating at 146 psi head pressure and 100°F condenser temperature, what is the subcooling measured?
  • Why is measuring compression ratio critical for a compressor's life?
  • What effect does temperature have on the performance of refrigeration systems during evacuation?
  • Where must the sensor bulb on a TEV be mounted?
  • During a system operation using R134A, what does the system indicate if the suction pressure falls to 15 psi and then into a vacuum?
  • What could be a potential risk if the compressor fails in a refrigeration system?
  • What does a dry system indicated by a moisture indicator imply for the refrigeration system's functionality?
  • What does proper refrigerant handling ensure?
  • Why is monitoring ambient temperature crucial in refrigeration systems?
  • What is a common characteristic of a high-quality vacuum pump used in system evacuation?
  • What is a key aspect of maintaining balanced port expansion valves?
  • If the oil sight glass in a compressor shows almost no oil and there are no leaks, what should be the next step?
  • When sizing the piping for a refrigeration system, which line is most critical?
  • What is the typical duration set for defrost timers in commercial freezers?
  • Why is it important to clean grease buildup on the condenser fan motor and blade?
  • What is the primary benefit of balanced port expansion valves?
  • When replacing a refrigerant cap tube with a generic cap tube kit, what is the first step to follow?
  • Why can pressure controls not be used as the sole source of temperature control in outdoor temperature climates?
  • What should be checked when a compressor is operating inefficiently?
  • Which type of cleaner is most effective for cleaning greasy condenser coils?
  • Which component removes heat from the refrigerant, allowing it to cool and condense?
  • What leads to effective acid removal from the refrigerant?
  • Which phrase best describes the proper use for a refrigerated box using a cap tube system?
  • What should be done if an evaporator has an external equalized TEV, but only an internal equalized valve is available?
  • Why is a proper refrigerant charge critical in refrigeration systems?
  • What condition can cause discharge valves and backing plates on a compressor valve plate to be deformed?
  • What function does the evaporator serve in a refrigeration system?
  • In subcooling calculations, why is the position of the temperature sensor important?
  • What is the recommended oil level in the sight glass of a running semi-hermetic compressor?
  • What is the main function of a drier in a refrigeration system?
  • What role do defrost timers play in commercial refrigeration systems?
  • A system that runs at a superheat of 1 ° F will likely result in what?
  • What does it indicate if a compressor is short-cycling?
  • If a start capacitor rated at 240 uf and 225 volts is faulty, which capacitor can be used instead?
  • What safety precautions should be observed while working with refrigeration systems?
  • What is typically the first sign of a cap tube issue?
  • How are cooler evaporators typically defrosted?
  • What symptom might indicate a faulty thermostat in a refrigeration unit?
  • When should a suction drier be left in the refrigeration line?
  • What is the main role of an accumulator in a refrigeration system?
  • What is the primary function of the compressor in a refrigeration system?
  • Which condition can lead to compressor failure due to high temperatures?
  • Where must the sensor bulb on a TEV be installed on the suction line?
  • What is the best example of the definition of a storage box?
  • What is the primary reason a condensing unit located in a restricted space will run higher than normal head pressures?
  • What factor can lead to compressor overheating in a refrigeration system?
  • What can cause frost build-up around the evaporator coil?
  • What is an essential part of routine maintenance for refrigeration systems?
  • What is important to consider when re-soldering refrigerant lines?
  • What is the most common cause of leaks in the middle of a copper line?
  • Which refrigerants are commonly used in commercial refrigeration systems?
  • Where should a trap be installed when piping refrigerant lines in a system with the compressor above the evaporator?
  • Why is refrigerant classification important for refrigeration systems?
  • What occurs to the water flow rate when the condensing unit is off?
  • Which box operates with higher humidity based on the temperature difference?
  • A water-cooled condenser that is operating properly will have what characteristic regarding discharge water temperature?
  • What maintenance action is necessary for a refrigeration compressor after a defrost cycle?
  • What does the capacity of a one horsepower compressor depend on?
  • What determines the size of the metering device needed for a refrigeration system?
  • What is the purpose of the suction line in a refrigeration system?
  • What is the most important line to ensure proper oil return during piping installation?
  • What is the status of contacts on a potential relay when not energized?
  • In a low-temperature refrigeration system, the majority of Btu of cooling is required to remove what?
  • Why do modern three-phase compressors often require crankcase pressure regulating (CPR) systems?
  • If the shroud is missing from the condenser on a condensing unit, what should be done?
  • How does a balanced port expansion valve differ from other types?
  • When replacing driers for newer refrigerants, what size should they be?
  • What should be done if there are bubbles in the sight glass of a refrigeration system?
  • When is it necessary to replace a compressor?
  • What is the procedure for checking the suction valves on a compressor?
  • What is a key disadvantage of using an automatic expansion valve?
  • Why is it necessary to remove a grease-covered condenser?
  • After completing repairs on a freezer, why might the temperature stop dropping at 35 degrees?
  • What is the primary purpose of a refrigeration system in commercial food service?
  • What is the importance of proper insulation in refrigeration systems?
  • Where is the most effective place to remove moisture from refrigerant?
  • What could indicate that a refrigeration system is overcharged?
  • What is an effect of not addressing low refrigerant levels?
  • Where is a pump down solenoid valve typically located?
  • What is the primary purpose of a thermal expansion valve in a refrigeration system?
  • An R404A cooler system with a cap tube has a head pressure of 336 psi. What may this indicate?
  • What is the primary purpose of a run capacitor in a compressor system?
  • What is the primary risk of using a run capacitor that is not functioning properly?
  • What is the best course of action when there are concerns with refrigerant levels in a compressor with low oil?
  • A missing condenser fan shroud on a cap tube system will probably lead to what?
  • The new interim refrigerants R401A, R401B, and R409A have what characteristic related to heat carrying capacity?
  • What is the primary function of the high-pressure switch in a refrigeration system?
  • If the TD of an evaporator coil should be 15 ° and you measure only 5 °, what could be the issue if other pressures check out?
  • What is superheat in the context of refrigeration?
  • When is it necessary to evacuate a refrigeration system?
  • Which cleaning agents are advisable for servicing refrigeration coils?
  • Which condition likely indicates a problem when turning off a refrigeration unit?
  • Why is it crucial to adhere to EPA regulations in refrigeration service?
  • How should one check the discharge valves on a compressor?
  • What is the maximum head pressure for an R404A system operating in an ambient temperature of 85°F?
  • Which component is responsible for maintaining the refrigerant flow in the system?
  • What is indicated by the terminal marked as 'A' in a common terminal identification?
  • Why might bubbles appear in sight glasses when using newer near azeotropic refrigerants?
  • What is a characteristic of a near azeotrop refrigerant?
  • What is the purpose of a low-pressure switch in refrigeration systems?
  • What is the maximum allowable discharge temperature to prevent probable compressor failure?
  • What type of maintenance is necessary for condensers in refrigeration systems?
  • Which refrigerant is a suitable interim replacement for R-12?
  • Where should a temperature sensor be installed to accurately calculate subcooling?
  • What happens to a refrigeration system when moisture is present?
  • What causes excess superheat increase on the way to the compressor?
  • What is a potential consequence of neglecting regular maintenance on refrigeration equipment?
  • What is a sign of a compressor burnout?
  • What action should be taken if the condenser is badly clogged?
  • What does the term 'latent heat' refer to in refrigeration contexts?
  • What could lead to a malfunctioning thermal expansion valve?
  • Where is a run capacitor connected in a motor system?
  • What can help mitigate the issue of bubbles showing in sight glasses with a full charge?
  • What is the function of a defrost termination thermostat on a walk-in freezer?
  • Why is regular maintenance important for refrigeration systems?
  • What instrument is used to measure the pressure in a refrigeration system?
  • What is a common reason for a refrigeration system to fail to activate cooling?
  • What is the role of the condenser in the refrigeration cycle?
  • What usually causes partial or complete clogging in capillary tubes?
  • What is the primary function of a fan delay thermostat in commercial freezers?
  • What is the role of the evaporator in a refrigeration system?
  • Which tool is essential for troubleshooting refrigeration issues?
  • What is a common issue with coolers and freezers that use a coiled discharge line in a pan for condensate removal?
  • What is a common cause for evaporator failures in reach-in coolers?
  • Which of the following is a key component in assessing the health of a refrigeration system?
  • What happens at the expansion valve in a refrigeration system?
  • What should you do if an ohmmeter reads infinity ohms when checking a start capacitor?
  • What line is typically used to provide heat for evaporating condensate in many commercial reach-in boxes?
  • What type of oil is most commonly used with CFC refrigerants?
  • When evacuating a refrigeration system, to what micron level should it ideally be evacuated?
  • When evacuating a refrigeration system, which tool is essential to ensure a proper evacuation?
  • If the suction line to a compressor using a TEV is frosted and iced up, it could indicate what issue?
  • In low temperature climates, what is the most efficient method for temperature control?
  • How should R404A be charged into a refrigeration system?
  • According to HACCP food safety regulations, what temperature must coolers maintain?
  • Which process occurs in the evaporator coil?
  • What is the maximum temperature a freezer must maintain to ensure proper operation?
  • How many BTUs per hour is one ton of refrigeration equal to?
  • What issue is indicated by the oil sight glass showing almost no oil in a compressor?
  • What is the main purpose of using a properly designed drier in a refrigeration system?
  • What is the main consequence of improper refrigerant charge?
  • Which factor is essential for maintaining optimal performance in a refrigeration system?
  • What happens when the defrost termination thermostat reaches its temperature limit?
  • What are signs indicating a malfunctioning expansion valve?
  • What does a dark brown or black color with carbon deposits on a compressor's valve plate indicate?
  • Why is a bleed resistor necessary on a start capacitor?
  • How does ambient temperature impact refrigeration system performance?
  • After servicing a cap tube system and replacing the drier with a larger one, what is the best way to recharge it?
  • Where should the discharge temperature be measured in a refrigeration system?
  • An automatic expansion valve does not:
  • Where should the sensor bulb on an external equalized TXV be mounted?
  • How can you identify a compressor that suffered from liquid slugging?
  • What is the main purpose of the expansion valve in refrigeration?
  • What is a thermal expansion valve (TXV) used for in refrigeration systems?
  • When should a condenser capacity be assessed?
  • How does a two-stage refrigeration system operate?
  • How can you confirm that a refrigeration system is properly charged?
  • When checking for correct superheat on a cap tube system, what condition is required?
  • What is an interim refrigerant choice for an R502 system with a major leak?
  • What is a major problem with POE oil?
  • If a cap tube is partially clogged, what is an expected condition?
  • What does the compression ratio represent in refrigeration systems?
  • What is a common reason for the premature failure of replacement compressors?
  • Which of the following is NOT a main component of a refrigeration system?
  • For maximum efficiency, the thermal expansion valve superheat for a freezer should be about:
  • How do you reduce the superheat on a thermal expansion valve?
  • How does a compressor function within a refrigeration system?
  • What type of contacts are found on a current relay?
  • Where should a sight glass/moisture indicator be installed in a refrigeration system?
  • What commonly contributes to high head pressure in a refrigeration unit?
  • For maximum system efficiency, the TEV superheat for a cooler should be about:
  • What type of oil is recommended for use with refrigerant R404A?
  • What impact do high superheat settings have on a refrigeration system?
  • Which of the following is a sign of a refrigerant leak?
  • What is subcooling in the context of refrigeration systems?
  • A cap tube is ineffective on most commercial refrigeration systems because:
  • How does regular maintenance benefit refrigeration systems?
  • What happens if the condenser fan fails in a refrigeration system?
  • If a compressor has a rated FLA of 20A but is drawing 26A while running, what is a possible issue?
  • What is a crucial reason for insulating the suction line?
  • Which component helps prevent corrosion in a refrigeration system?
  • If the liquid line out of the liquid line drier is frosted, what does this suggest?
  • In order to maintain proper temperature under various loads, a cooler or freezer located on a front prep line must be equipped with:
  • What is a major consequence of undercharging a refrigeration system?
  • What is a typical symptom of a malfunctioning compressor?
  • What is the total capacitance of two 100 uf capacitors connected in parallel?
  • When replacing valve plates or service valves, what should be used to lubricate the gaskets?
  • What characteristic of mineral oil makes it suitable for use with CFC refrigerants?
  • Why is superheat crucial in a refrigeration system?
  • If an R404A system has a suction pressure of 29 psi and a head pressure of 239 psi, what is the superheat?
  • What does the milky color of oil in a compressor most likely indicate?
  • What is a possible cause for the suction valves snapping off when the compressor head is removed?
  • Why must a condenser fan blade be replaced with the exact factory-supplied blade?
  • Which refrigerant would you convert a walk-in freezer to when replacing the condensing unit on an R502 system?
  • What is a potential consequence of improper refrigerant levels in a refrigeration system?
  • When converting a system from R502 to R404A, what can you do with the TEV?
  • How should a fan blade be positioned in an evaporator or condenser?
  • What is a common indicator of a clogged filter in a refrigeration system?
  • Where must a static condenser be installed?
  • Which of the following best describes the process of condensation in a refrigeration system?
  • What does the coefficient of performance (COP) indicate?
  • A dark colored moisture indicator sensor suggests what condition in a refrigeration system?
  • What is the consequence of dirty and clogged evaporator coils?
  • What effect does a missing condenser fan shroud have on discharge pressure?
  • What are common refrigerant types used in commercial kitchens?
  • When should a cap tube be considered for use in a refrigeration system?
  • Where is the best location to remove acid from a refrigerant system?
  • What pressure corresponds to 20°F on R404A?
  • Is it advisable to install a sight glass in a cap tube system?
  • When a compressor kicks the circuit breaker while starting, what could be the likely problem if the FLA rating is 7 amps?
  • What should be monitored to prevent damage to relay contacts in a compressor's circuitry?
  • What is the purpose of a condenser in the refrigeration cycle?
  • What is the appropriate method to perform a leak check in a refrigeration system?
  • What is the role of an electrical schematic in refrigeration troubleshooting?
  • What causes a refrigeration system to run continuously?
  • What is the maximum allowable voltage difference for a balanced three-phase compressor?
  • Why are forced air evaporator coils commonly used in refrigeration systems?
  • What is the benefit of using leak detectors in refrigeration maintenance?
  • What is one way to maintain proper airflow in a refrigeration system?
  • When bubbles are present in a sight glass, what does this indicate when using near azeotropic refrigerants?
  • What environmental factor can contribute to compressor failures?
  • What does icing around a freezer door frame typically indicate?
  • What must be matched when replacing an evaporator fan motor?
  • What preventative measures can help avoid compressor failure?
  • What is the purpose of an evaporator fan in commercial refrigeration?
  • What is a significant advantage of a balanced port TEV?
  • What is true about compression ratio in relation to volumetric efficiency?
  • What is the primary function of an accumulator in a refrigeration system?
  • What equipment should be installed to handle the system for newer refrigerants?
  • How is a coil on a current relay typically connected?
  • What environmental factor significantly impacts the efficiency of condensing units in refrigeration systems?
  • What is the purpose of a water regulating valve in a water-cooled condenser?
  • In refrigeration systems, what role does a sight glass play when properly installed?
  • What is a common method to identify leaks in a refrigeration system?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy